The Eaton CHB270 is a 70 Amp, two-pole circuit breaker designed for Eaton CH Loadcenters, and it’s commonly used when you need a direct replacement that matches what’s already installed in an existing panel. It’s built for 120/240V circuits where both legs need to trip together, and it installs into compatible CH series panels using a plug-in design that keeps everything aligned with the original setup.
In real-world use, this breaker is typically found in residential and light-commercial panels, handling larger 240V branch circuits. Most of the time, it’s chosen for replacement work where the goal is simple—to match the existing breaker so the system continues operating as originally designed, without changing the panel layout or wiring.
If you’re replacing an existing CH breaker, it’s usually a quick, familiar process—remove the old one, install the new breaker, and the circuit is back in service. Inside, the CHB270 uses a thermal-magnetic trip system that responds to both overload conditions and short circuits as they occur. It’s rated at 10 kAIC, which is standard for residential and light commercial fault levels in CH systems.
With support for #8–2 AWG conductors, it accommodates the heavier wiring commonly used on 70-amp branch circuits. The two-pole design ensures both conductors disconnect at the same time, which is required for 240V loads and any circuit that shares protection across both legs.
Key Features and Benefits
- 70 Amp, 2-pole breaker for Eaton CH Loadcenters
- Designed for 120/240V branch circuits
- Plug-in installation for compatible CH panels
- Thermal magnetic protection for overloads and short circuits
- 10 kAIC interrupt rating for standard fault conditions
- Compatible with #8–2 AWG conductors
- Two-pole switching for simultaneous disconnect
- Maintains original CH panel configuration
- Common in residential and light commercial systems
- Direct replacement for existing CH breakers
Technical Specifications
-
Catalog Number: CHB270
-
Product Type: Thermal magnetic circuit breaker
-
Type: CHB
-
Amperage Rating: 70 Amps
-
Voltage Rating: 120/240V
-
Number of Poles: 2
-
Interrupt Rating: 10 kAIC
-
Wire Size: #8–2 AWG
-
Mounting Style: Plug-in (Eaton CH Loadcenters)
-
Dimensions: 3.7 in D x 3.2 in H x 2.2 in W
- Weight: 0.9 lb
Material Compliance and Certifications
- The Eaton CHB270 is UL 489-listed, meeting recognized safety standards for branch-circuit protection. It is intended for installation in Eaton CH Loadcenters and should be installed by qualified electrical personnel in accordance with all applicable electrical codes and safety requirements.
Where It Works Best
- Eaton CH Loadcenters and CH panelboards
- 120/240V residential and light commercial circuits
- Two-pole branch circuits requiring a shared disconnect
- Replacement of existing CH 70A breakers
- Maintenance work on installed CH electrical systems
- Circuits that require both legs to trip together
- Situations where matching the existing panel layout matters
- Standard protection in established CH systems
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:1.5
- Height:3.0
- Depth:2.5
- Poles:2
- Amperes:70
- A.I.C. Rating & Volts:10k @ 120/240VAC
- Type:CHB
- Approx Dimensions:1.50"W x 3.00"L x 2.50"D
- Additional Notes:Bolt-on style Circuit Breaker
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).