DK2350Y - 350Amp Circuit Breaker



- 350 Amp
- 65k @ 240VAC
- 2 Pole
Purchase Options: New In Box
DK2350Y - 350Amp Circuit Breaker Description
DK2350Y - 350Amp Circuit Breaker
The DK2350Y is a 350 Amp, 2-pole thermal magnetic circuit breaker designed for dependable overcurrent protection in commercial and industrial electrical systems. When you're maintaining existing equipment or replacing a breaker in a compatible K-Frame installation, matching the original specifications is critical. This breaker is built to provide the proper form, fit, and function required for those applications while helping maintain the integrity of the electrical distribution system.
With a 65kA interrupting rating at 240VAC, the DK2350Y is designed to respond to overloads and short-circuit conditions before they can cause damage to connected equipment. Its thermal magnetic trip mechanism combines protection against both sustained overcurrents and sudden fault events, making it a common choice in power distribution systems where reliable circuit protection is essential.
Built to last and designed for compatibility with existing K-Frame systems, the DK2350Y is frequently used in manufacturing facilities, commercial buildings, institutional properties, and other demanding electrical environments. Whether you're replacing a failed unit during maintenance or supporting a larger equipment refurbishment project, this circuit breaker helps maintain the original protection characteristics and electrical ratings of the system.
Key Features and Benefits
- 350 Amp continuous current rating
- 2-pole thermal magnetic circuit breaker
- K-Frame construction
- 65kA interrupting capacity at 240VAC
- Non-interchangeable trip unit
- Includes line-side lugs
- Designed for operation in 40°C ambient conditions
- HACR rated for heating, air conditioning, and refrigeration applications
- Provides overload and short-circuit protection
- Commonly used in commercial and industrial power distribution systems
- Frequently installed during maintenance, repair, and replacement projects
- Helps maintain original equipment ratings and configuration
- Built to last for long-term service in demanding environments
Technical Specifications
-
Part Number: DK2350Y
-
Type: DK
-
Circuit Breaker Style: Thermal Magnetic Circuit Breaker
-
Frame Size: K-Frame
-
Poles: 2
-
Amperage Rating: 350 Amps
-
Interrupting Capacity: 65kA @ 240VAC
-
Trip Unit: Non-Interchangeable
-
Operating Temperature Rating: 40°C
-
HACR Rated: Yes
-
Lug Configuration: Includes Line-Side Lugs
-
Width: 5.50 in.
-
Height (Length): 10.13 in.
-
Depth: 4.10 in.
-
Dimensions: 5.50"W × 10.13"L × 4.10"D
-
Approximate Shipping Weight: 13.50 lbs.
Material Compliance and Certifications
- HACR Rated: Manufactured for use in electrical distribution applications requiring properly rated overcurrent protection.
- Installation Requirements: Designed for installation in accordance with applicable electrical codes and equipment specifications.
- Qualified Personnel: Intended for use by qualified electrical professionals.
-
Application Suitability: Suitable for applications requiring a thermal magnetic molded case circuit breaker with a non-interchangeable trip unit.
Where It Works Best
- Commercial electrical distribution systems
- Industrial facilities and manufacturing plants
- Mechanical equipment power distribution
- HVAC and refrigeration systems requiring HACR-rated protection
- Distribution panels and switchgear applications
- Feeder circuit protection
- Facility maintenance and repair projects
- Electrical system refurbishment programs
- Existing K-Frame installations requiring compatible replacement breakers
- Applications requiring 350 Amp, 2-pole circuit protection with 65kA interrupting capacity
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:5.5
- Height:10.13
- Depth:4.1
- Poles:2
- Amperes:350
- A.I.C. Rating & Volts:65k @ 240VAC
- Type:DK
- Approx Dimensions:5.50"W x 10.13"L x 4.10"D
- Additional Notes:40°C, HACR Rated, K-Frame, Thermal Magnetic Circuit Breaker with Non-Interchangeable Trip Unit. Includes Line-Side Lugs
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).