EHB3040L - 40Amp Circuit Breaker


- 40 Amp
- 14k @ 480VAC
- 3 Pole
Purchase Options: Refurbished
EHB3040L - 40Amp Circuit Breaker Description
EHB3040L - 40Amp Circuit Breaker
Finding the right replacement circuit breaker is about more than matching the amperage. The EHB3040L is a 3-pole, 40-amp Type EHB thermal-magnetic circuit breaker designed to provide the form, fit, and functional compatibility required for electrical systems using compatible pre-1989 panelboards. If you're maintaining an existing commercial or industrial electrical system, selecting a breaker with the correct type, interrupting rating, pole configuration, and terminal arrangement helps keep the equipment operating as originally designed.
Whether you're replacing a failed breaker during maintenance or stocking a critical spare for an older facility, the EHB3040L provides the compatibility needed to keep legacy electrical systems in operation.
Key Features and Benefits
- Designed as a form, fit, and functional replacement for compatible Type EHB circuit breakers
- 40 Amp current rating for dependable branch circuit protection
- Three-pole design for compatible three-phase electrical systems
- Thermal-magnetic trip mechanism helps protect against overloads and short circuits
- Non-interchangeable trip unit maintains the original breaker configuration
- Rated for operation in ambient temperatures up to 40°C
- Includes line and load terminals
- Designed for compatible panelboards manufactured before 1989
- Built to last for continued use in legacy electrical distribution systems
Technical Specifications
-
Part Number: EHB3040L
-
Type: EHB
-
Poles: 3
-
Amperage: 40 Amps
-
Trip Unit: Thermal-Magnetic, Non-Interchangeable
-
Interrupting Rating: 14kA @ 480VAC
-
Temperature Rating: 40°C
-
Line Terminals: Included
-
Load Terminals: Included
-
Compatible Equipment: Panelboards manufactured before 1989
-
Dimensions:
- Width: 4.13 inches
- Length: 6.00 inches
- Depth: 3.38 inches
-
Approximate Shipping Weight: 5.50 lbs.
Material Compliance and Certifications
- Designed for installation in compatible electrical distribution equipment.
- Always verify compatibility by confirming the breaker type, amperage, voltage rating, interrupting capacity, pole configuration, mounting style, and terminal configuration before installation.
- Installation should be performed by qualified electrical personnel and in accordance with applicable electrical codes.
- Confirm compatibility with the original equipment manufacturer's specifications before placing the breaker into service.
Where It Works Best
The EHB3040L is commonly used in commercial, industrial, and institutional facilities where legacy electrical distribution equipment remains in service. It is well suited for manufacturing plants, warehouses, office buildings, schools, hospitals, and similar environments that rely on compatible pre-1989 panelboards. When the original equipment specifications call for a Type EHB, 3-pole, 40-amp thermal-magnetic circuit breaker with a 14kA interrupting rating at 480VAC, this breaker provides the form, fit, and functional compatibility needed to maintain the existing electrical system without modifications.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:4.13
- Height:6.0
- Depth:3.38
- Poles:3
- Amperes:40
- A.I.C. Rating & Volts:14k @ 480VAC
- Type:EHB
- Approx Dimensions:4.13"W x 6.00"H x 3.38"D
- Additional Notes:Thermal-magnetic circuit breaker with non-interchangeable trip unit. 40°C rated. This item includes line and load terminals. This breaker was designed for panels that were manufactured before 1989
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).