HRXD63B180 - 1800Amp Circuit Breaker

- 1800 Amp
- 50k @ 600VAC; 65k @ 480VAC; 100k @ 240VAC
- 3 Pole
Purchase Options:
HRXD63B180 - 1800Amp Circuit Breaker Description
HRXD63B180 - 1800Amp Circuit Breaker
Matching a replacement breaker is a detail-driven job, especially when you're working with existing electrical equipment. The Siemens HRXD63B180 is a 1800A, 3-pole SENTRON molded case circuit breaker built around the RD frame and rated for 600V. For anyone sourcing a breaker for compatible legacy equipment, these specifics make it easier to evaluate form, fit, and function without relying on assumptions. The HRXD63B180 is built to last, but proper application still depends on confirming all critical electrical and physical specifications before installation.
Key Features and Benefits
- 1800A current rating: Provides the specified amperage for compatible equipment requiring an 1800-amp RD-frame breaker.
- 3-pole configuration: Gives you a straightforward specification to match against the breaker being replaced and the existing electrical system.
- 600V rating: Rated for 600V operation when used in compatible equipment and within its other specified ratings.
- Thermal-magnetic trip unit: Uses the trip technology identified by Siemens for this SENTRON molded case circuit breaker.
- Non-interchangeable trip: The fixed trip configuration is an important compatibility point when matching an existing breaker.
- No lugs installed: This particular configuration is supplied without installed lugs so that connection requirements can be evaluated separately as part of the equipment match.
Technical Specifications
-
Manufacturer: Siemens
-
Catalog Number / MFN: HRXD63B180
-
Article Number: US2:HRXD63B180
-
Product Line: SENTRON
-
Product Type: Molded Case Circuit Breaker
-
Product Family: HRD6, 50 kAIC, 600 VAC
-
Frame: RD
-
Rated Current: 1800 A
-
Number of Poles: 3
-
Voltage Rating: 600 V
-
Interrupt Rating at 600 V: 50 kAIC
-
Interrupt Rating at 480 V: 65 kAIC
-
Trip Unit: Thermal-Magnetic
-
Trip Configuration: Non-Interchangeable
-
Temperature Designation: Standard 40°C breaker
-
Lugs: No lugs installed
-
Dimensions (W x H x D): 9 x 16 x 6.19 in.
-
Width: 9 in.
-
Height: 16 in.
-
Depth: 6.19 in.
-
Net Weight: 46.8 lb.
-
Standards: Meets UL 489 / IEC 60947-2
-
UPC: 783643247765
-
Commodity Code: 85362099
-
Export Classification: EAR99
-
Country of Origin: Mexico
-
Dangerous Goods: No
Material Compliance and Certifications
According to the supplied Siemens specifications, the HRXD63B180 meets UL 489 and IEC 60947-2 standards. This distinction is worth keeping precise: the supplied product information states that the breaker meets these standards, so no additional listing or certification claim is being inferred.
Where It Works Best
The Siemens HRXD63B180 1800A circuit breaker is appropriate for compatible existing and legacy electrical equipment that calls for its specific combination of RD frame, 1800A rating, three-pole, 600V rating, thermal-magnetic non-interchangeable trip, physical dimensions, and applicable interrupting rating. Because this model comes without lugs installed, connection requirements deserve particular attention when evaluating it as a form, fit, and functional replacement.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.
Specifications
- Width:9.0
- Height:16.0
- Depth:6.19
- Poles:3
- Amperes:1800
- A.I.C. Rating & Volts:50k @ 600VAC; 65k @ 480VAC; 100k @ 240VAC
- Type:HRXD6
- Approx Dimensions:9.00"W x 16.00"L x 6.19"D
- Additional Notes:RD2000A Frame, Thermal Magnetic, Molded Case Circuit Breaker With Non-Interchangeable Trip Unit. Does Not Include Any Lug Terminals - discontinued by the Manufacturer
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).