JA3125W - 125Amp Circuit Breaker


- 125 Amp
- 22k @ 600VAC; 22k @ 480VAC; 25k @ 240VAC
- 3 Pole
Purchase Options:
JA3125W - 125Amp Circuit Breaker Description
JA3125W - 125Amp Circuit Breaker
When you're matching a breaker for existing equipment, small configuration details can make a big difference. The JA3125W is a 125-amp, 3-pole Type JA circuit breaker with a thermal-magnetic, non-interchangeable trip unit. For compatible legacy equipment that requires these electrical and physical characteristics, the JA3125W provides a clearly specified form, fit, and function replacement option. These products are built to last, but proper selection still depends on matching the complete breaker specifications to the equipment requirements.
Key Features and Benefits
- 125-amp rating: Provides a straightforward specification to compare with the breaker being replaced and the equipment requirements.
- Three-pole configuration: Designed for equipment specifically requiring a 3-pole breaker arrangement.
- Type JA: Helps narrow the replacement search when existing documentation or breaker markings specify Type JA.
- Thermal-magnetic trip: Uses the specified thermal-magnetic circuit breaker design.
- Non-interchangeable trip unit: An important configuration detail to confirm when matching an existing breaker.
- No terminals included: The JA3125W is supplied without terminals, making terminal requirements an essential part of the compatibility check.
Technical Specifications
-
Part Number: JA3125W
-
Product Type: Circuit Breaker
-
Type: JA
-
Amperage: 125 A
-
Poles: 3
-
A.I.C. Rating at 600VAC: 22k
-
A.I.C. Rating at 480VAC: 22k
-
A.I.C. Rating at 240VAC: 25k
-
Interrupting Capacity at 600VAC: 22,000 A
-
Interrupting Capacity at 480VAC: 22,000 A
-
Interrupting Capacity at 240VAC: 25,000 A
-
Trip Type: Thermal-Magnetic
-
Trip Unit: Non-Interchangeable
-
Temperature Rating: 40°C
-
Terminals: Not Included
-
Width: 5.50 in.
-
Height / Length: 10.13 in.
-
Depth: 3.94 in.
-
Overall Dimensions: 5.50"W x 10.13"L x 3.94"D
-
Approximate Ship Weight: 16.00 lb.
Material Compliance and Certifications
No specific UL, CSA, IEC, RoHS, REACH, or other certification or material compliance information was provided for the JA3125W. Those certifications should not be assumed from the breaker type or electrical ratings. Where a particular certification or compliance requirement applies, verify it against the product markings and applicable manufacturer documentation.
Where It Works Best
The JA3125W makes sense for compatible existing and legacy electrical equipment that specifically requires a 125A, 3-pole Type JA thermal-magnetic circuit breaker with a non-interchangeable trip unit and matching voltage-dependent interrupting ratings. Because terminals are not included, that detail should be checked carefully against the installation requirements rather than assuming this configuration is interchangeable with a terminal-equipped version.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Specifications
- Width:5.5
- Height:10.13
- Depth:3.94
- Poles:3
- Amperes:125
- A.I.C. Rating & Volts:22k @ 600VAC; 22k @ 480VAC; 25k @ 240VAC
- Type:JA
- Approx Dimensions:5.50"W x 10.13"L x 3.94"D
- Additional Notes:40°C Rated, Thermal Magnetic Circuit Breaker With Non-Interchangeable Trip Unit. This item does NOT include any terminals. - discontinued by the Manufacturer
Returns are easy
You may return unused items within 30 days of delivery for a full refund.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).