TED124100WL - 100Amp Circuit Breaker


- 100 Amp
- 18k @ 480VAC; 18k @ 240VAC
- 2 Pole
Purchase Options:
TED124100WL - 100Amp Circuit Breaker Description
TED124100WL - 100Amp Circuit Breaker
The ABB TED124100WL is a 100-amp, 2-pole thermal-magnetic molded-case circuit breaker from ABB's E150 product family, designed to protect circuits in compatible commercial and industrial electrical systems.
Note the WL suffix. ABB uses this designation to identify breakers supplied with copper/aluminum (Cu/Al) line and load lugs, which matters when you're matching a replacement to an existing installation.
Key Features and Benefits
- 100-Amp Current Rating
- Two-Pole Circuit Breaker Configuration
- Thermal-Magnetic Circuit Protection
- Fixed Long-Time and Instantaneous (LI) Trip Function
- Non-Interchangeable Trip Mechanism
- ABB E150 Frame Construction
- Cu/Al Line and Load Lugs Included
- 480VAC and 250VDC Voltage Ratings
- 18 kAIC AC Interrupting Rating
- 10 kAIC DC Interrupting Rating
- Suitable for Reverse Feed
- HACR Marking
- 60/75°C Conductor Temperature Rating
- Form, Fit, and Functional Replacement
- Built to Last
Technical Specifications
-
Manufacturer: ABB
-
Catalog Number: TED124100WL
-
Manufacturer Description: ASM CIRCUIT BREAKER
-
Product Type: Molded-Case Circuit Breaker
-
Breaker Category: Thermal Magnetic
-
Product Line: Thermal Magnetic
-
Product Series: TED
-
Product Family: E150
-
Frame Type: E150
-
Number of Poles: 2
-
Rated Current: 100 Amps
-
Trip Style: Non-Interchangeable
-
Trip Function: LI (Long-Time and Instantaneous)
-
Long-Time Trip Setting: Fixed
-
Instantaneous Trip Setting: Fixed
-
Continuous Current Rating Classification: Standard
-
AC System Voltage Ratings: 120VAC, 120/240VAC, 240VAC, 277VAC, 480VAC
-
DC System Voltage Ratings: 125VDC, 250VDC
-
120VAC Interrupting Rating: 18 kAIC
-
120/240VAC Interrupting Rating: 18 kAIC
-
240VAC Interrupting Rating: 18 kAIC
-
277VAC Interrupting Rating: 18 kAIC
-
480VAC Interrupting Rating: 18 kAIC
-
125VDC Interrupting Rating: 10 kAIC
-
250VDC Interrupting Rating: 10 kAIC
-
Line and Load Lugs: Included, copper/aluminum (Cu/Al), as indicated by the WL suffix
-
Manufacturer-Listed Lug Designations: TC041, TCAL15
-
Reverse-Feed Suitability: Yes
-
Conductor Temperature Rating: 60/75°C, based on ABB's E150 family rating for breakers through 100 amps
-
Current Metering: No
-
Protective Relays: No
-
Special Markings: HACR
-
GO Schedule: EB
-
UPC: 783164068214
-
GSA Compliance: No
-
Environmental Product Declaration Status: No Declaration Needed
Material Compliance and Certifications
Consider the listed file numbers, markings, and terminal information alongside the equipment's electrical ratings and applicable installation instructions.
- UL File Number: E11592
- CSA File Number: LR57114
- HACR Marking: Manufacturer-listed special marking
- GSA Compliance: No
- Environmental Product Declaration: No Declaration Needed
Where It Works Best
- Existing Commercial Electrical Systems
- Industrial Electrical Maintenance
- Legacy Electrical Equipment
- Matching Circuit Breaker Replacements
- Compatible 480VAC Electrical Applications
- Compatible 250VDC Electrical Applications
- Two-Pole Circuit Protection
- ABB E150 Frame Applications
- Electrical Distribution Equipment Maintenance
- Reverse-Feed Electrical Arrangements
- HACR-Marked Breaker Applications
- Existing Installations Requiring Cu/Al Line and Load Lugs
- Facility Maintenance and Electrical Repairs
- Form, Fit, and Functional Replacement Projects
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
GE®, and ABB® are registered trademarks of General Electric Company and ABB Ltd., respectively. Products sold are surplus, used, or refurbished and are NOT supplied by General Electric Company or ABB Ltd., or their affiliates.
Specifications
- Width:2.75
- Height:6.31
- Depth:3.38
- Poles:2
- Amperes:100
- A.I.C. Rating & Volts:18k @ 480VAC; 18k @ 240VAC
- Type:TED
- Approx Dimensions:2.75"W x 6.31"L x 3.38"D
- Additional Notes:Molded Case Industrial Circuit Breaker with Non-Interchangeable Thermal Magnetic Trip Unit. Includes Line and Load-Side Lugs - discontinued by the Manufacturer
Returns are easy
You may return unused items within 30 days of delivery for a refund, subject to our Return Policy.
FREE ground shipping on breaker orders over $100 and all other items with orders over $500.
Shipping charges are Prepaid and Allowed on UPS Ground orders for all other products on orders over $500.00, again only when shipping within the lower 48 continental United States, provided the product(s) can safely ship UPS Ground.
If the product cannot safely ship via UPS Ground, or is too heavy to ship UPS Ground, then the product will be shipped via freightliner at buyer's expense.
CIRCUIT BREAKER SUPERSTORE® offers one to five day delivery in the United States. The variation depends on the chosen shipping speed and the warehouse location for the product(s).
Same Day Shipping
We strive to ship out your items within one business day.
In rare circumstances, CIRCUIT BREAKER SUPERSTORE® may reserve up to 5 business days to complete shipment. Feel free to contact us if your order is time sensitive.
CIRCUIT BREAKER SUPERSTORE® provides a limited 1-year warranty on both new and reconditioned products. Rest assured, all products are authentic OEM (original equipment manufacturer).